9kg Dry Chemical ABE Powder Fire Extinguisher

Price:

$80.00 inc. GST

Inc. Tax: $88.00

ABE (Powder) Fire Extinguisher - Sign Kit

Get the Maintenance Tag stamped by us

Or Call Us

Bulk Pricing

QuantityPrice
2 - 5 $77.60
6 - 10 $75.20
11 + $73.60

Description

Commander™ 9.0kg ABE Dry Chemical Powder Fire Extinguisher

The Commander 9kg ABE fire extinguisher carries a 6A:80B:E fire test rating and is certified to AS/NZS 1841.5. It is the highest rated portable unit in the Commander range.

Specifications

  • Agent: monoammonium phosphate (MAP) dry chemical powder
  • Capacity: 9.0kg
  • Fire test rating: 6A:80B:E
  • Standard: AS/NZS 1841.5
  • Dimensions: 590mm (H) x 205mm (W) x 195mm (D)
  • Finish: epoxy coated red, UV resistant
  • Handle and safety pin: stainless steel
  • Valve: brass
  • Model: CP90ABE
  • Supplied with: flexible rubber hose, wall bracket, AS 1851 maintenance tag
  • Bulk pricing applies from two units
  • Warranty: 1 year

Fires It Can Handle

Class A, Class B and Class E, as stated by the 6A:80B:E rating.
  • Class A: timber, paper, cardboard, textiles.
  • Class B: petrol, diesel, oils, paints, solvents.
  • Class E: energised electrical equipment.
Powder interrupts the chemical reaction sustaining the flame, and on Class A material the MAP melts and seals the surface against reignition. The 80B rating is the reason this size gets specified around bulk fuel, plant refuelling and workshop chemical stores, where a spill fire covers more surface than a smaller unit can knock down.

Where Not to Use It

  • Class C combustible gases
  • Class D combustible metals
  • Class F cooking oils and fats: powder is not rated for deep fryers or range tops. Kitchens need a wet chemical unit and a fire blanket

What Powder Leaves Behind

The residue is corrosive and draws moisture once it settles. On a switchboard, a server or a control panel, that turns a contained fire into an equipment replacement plus a clean-up before anyone works in the space again. Where electrical risk is the primary concern and the equipment matters, CO2 discharges without residue and leaves the equipment recoverable.Discharged in an enclosed space, powder also removes visibility almost immediately. Get out and stay out once you have discharged it.

Check Who Can Lift It

At 9kg of agent plus the cylinder, this is a two-hand lift off the bracket and a heavy unit to hold steady through a full discharge. Coverage only counts if someone on shift can take it down and use it.Before specifying the 9kg across a site, work through:
  • Whether the people working in that area can lift and operate it
  • Whether the mounting substrate takes the loaded weight
  • Whether two 4.5kg units positioned separately serve the area better than one 9kg
The last point is a placement question rather than a substitution. Under AS 2444 smaller units cannot be combined to meet a required rating, so if the assessment calls for 6A, the 9kg is what meets it. Where the required rating is lower, spreading 4.5kg units shortens travel distance and puts a usable extinguisher in more hands.

Where This Size Fits

Heavy industry, mining, mine site vehicles, earthmoving and heavy plant, warehouses and factories, service stations and fuel storage, transport depots, farm machinery, and large marine applications.AS 2444 sizes coverage by rating rather than by weight, so compare the rating on the label before the kilograms. Our AS 2444 selection guide sets out how type and coverage get calculated together.

How to Identify an ABE Extinguisher

Red body with a white band. Full breakdown in our fire extinguisher colour code guide.

Mounting and Placement

Under AS 2444:
  • Base at least 100mm clear of the floor
  • Top of the handle no higher than 1,200mm
  • Maximum 15 metres travel distance from any point on the floor to the nearest Class A extinguisher, measured along the path a person walks
  • Smaller units cannot be combined to substitute for one unit of the required rating
Where a unit sits in a plant room, a yard or anywhere it takes knocks and weather, a cabinet or stand protects it and holds it at a consistent height.

Signage Requirements

AS 2444 requires an identification sign above each extinguisher, mounted at 2 to 2.5 metres so the type and its fire classes are readable on approach. An extinguisher without a compliant sign fails the placement check regardless of the unit's own certification.

Servicing and Maintenance

Under AS 1851-2012:
  • Six-monthly inspection by a competent person
  • Yearly detailed service, including signage, location and bracket check
  • Hydrostatic pressure test at five years
Any extinguisher that has been discharged, even partly, requires service immediately rather than at the next scheduled visit. Units on mobile plant and mine vehicles take constant vibration, which settles the powder and loosens mountings, so those warrant close attention at every inspection. Intervals and record-keeping detail in our fire testing intervals guide. Manufacture sits under the ACCC mandatory standard for portable non-aerosol fire extinguishers.

Site Coverage and Bulk Orders

We supply, install and position first-responder fire equipment against AS 2444 for heavy industry, mining, construction and commercial sites across Australia. Call 1800 273 473 or see the full Commander fire extinguisher range.

Payment & Security

Visa PayPal Mastercard Maestro American Express

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

Reviews

There are no reviews yet.

Be the first to review “9kg Dry Chemical ABE Powder Fire Extinguisher”

Your email address will not be published. Required fields are marked *

You may also be interested in