The Temporary Fire Alarm Mistake Most Sites Make

The Temporary Fire Alarm Mistake Most Sites Make
14 July 2022

A temporary fire alarm exists to solve a specific problem: a building under construction has no working fire system, no power in half the structure, and a workforce spread across levels that change every week. The permanent system goes in near the end. The risk starts on day one. This guide covers what a temporary alarm needs to do on a site, which detectors suit which conditions, and the mistake that leaves a site effectively unprotected.

Why a site needs one before the permanent system exists

A construction site is one of the highest-risk fire environments there is. Hot works, temporary power, flammable materials, timber framing, gas bottles, and no compartmentation yet to slow a fire down. Meanwhile the fixed detection and alarm system that will eventually protect the building doesn't exist.

That gap can last months. A temporary alarm fills it. It has to raise the alarm across a site where nothing is wired, where the layout changes as the build progresses, and where the noise makes a quiet alarm useless.

Welder cutting steel reinforcement on a construction site, sparks falling near timber formwork

What a temporary fire alarm has to do

The requirements are practical, and they're different from a permanent installation:

  • Work without cabling. Nothing is wired yet, so the system runs wireless and battery-powered.
  • Be heard over the site. Concrete saws and generators drown out a domestic-volume alarm. Site sounders need the decibels to cut through.
  • Move as the site moves. Levels open up, walls go in, work zones shift. Units have to reposition without rewiring.
  • Cover the whole site, not one zone. A worker on level four needs to hear an alarm raised in the basement.
  • Keep working through a power cut. Battery backup isn't optional on a site where temporary power drops out.

The whole point is coverage that keeps pace with the build. A system you have to re-engineer every time the site changes is a system that quietly stops covering things.

Choosing the detector: dust changes the answer

This is where most advice goes wrong, because it borrows from residential guidance without accounting for the site.

Fire authorities across Australia recommend photoelectric smoke alarms for general life safety, and for good reason. Photoelectric units detect slow, smouldering fires far faster, the kind that start in wiring or bedding and produce thick smoke for a long time before flames appear. Ionisation units are quicker on fast-flaming fires but slower on smouldering ones, and they false-alarm more readily. Queensland and the Northern Territory are phasing ionisation out entirely.

Concrete cutting throws dust through an unfinished building, the conditions a temporary fire alarm has to work in

But here's the catch on a construction site: smoke detectors of any kind nuisance-trigger in dusty air. Cutting, grinding, and sweeping generate exactly the airborne particles a smoke detector is built to notice. A site that suffers constant false alarms is a site where people start ignoring the alarm, or disabling it, which is worse than having no alarm at all.

That's why a heat detector is often the right answer on a site rather than a compromise. It responds to a rapid rise in temperature instead of smoke particles, so dust doesn't set it off. In dusty, dirty, high-particulate areas, a heat detector gives you reliable detection that people will actually trust.

Where the environment is cleaner, a smoke detector gives earlier warning, because smoke precedes heat. Many sites run both: smoke detection in site offices, amenities, and finished areas, heat detection where the dust is.

The manual call point

Detection is only half of it. Most fires on a site are seen by a person before any detector notices them, which makes the manual call point the most-used device in the system. A worker sees a fire, hits the point, and the whole site knows.

Call points need to sit where people actually walk, at exits, near hot works, on every level, and they need to be part of the same wireless network as everything else so one press sounds every unit on site.

The mistake that leaves a site unprotected

The common failure isn't buying the wrong equipment. It's letting the coverage fall behind the build.
A system set up when the site was a slab and a fence doesn't cover a four-storey structure six months later. Units get moved for a concrete pour and never go back. A level opens up and nobody adds a sounder. Nobody notices, because nothing tests it.

Test the alarm regularly, and re-check coverage every time the site layout changes. A temporary system that isn't maintained is a compliance box ticked and a risk left open.

Setting one up properly

For the practical detail of deploying a system across a live site, control panels, zoning, call point placement, and documentation, our guide on deploying a Cygnus alarm system across a site walks through it. If you're still weighing options, our guide to our wireless alarm system range covers what to look for.

Fire and Rescue NSW's guidance on fire safety equipment is a useful baseline on how detection and alarm equipment should be used.

If your site's alarm coverage hasn't been reviewed since the slab went down, that's worth an hour of someone's time. Take a look at our wireless alarm systems, or tell us what you're building and we'll work out what the site needs.

A temporary fire alarm is a wireless, battery-powered alarm system used on a site that has no permanent fire detection yet, most often a construction site. It provides detection, manual call points, and site-wide sounders that can be repositioned as the build progresses, then removed once the permanent system is commissioned.

Yes. A construction site carries high fire risk from hot works, temporary power, and flammable materials, and the permanent system doesn't exist until late in the build. A temporary alarm covers that gap, and workers need a way to raise and hear an alarm across the whole site.

It depends on the area. Smoke detectors give earlier warning but nuisance-trigger in dusty air, which is a constant problem on a site where cutting and grinding are happening. Heat detectors respond to a rapid temperature rise instead, so dust doesn't set them off. Many sites use heat detection in dusty zones and smoke detection in site offices and finished areas.

Photoelectric alarms detect slow, smouldering fires much faster, which is the type most likely to kill someone, and they false-alarm less. Ionisation alarms respond faster to fast-flaming fires but are slower on smouldering ones. Australian fire authorities recommend photoelectric, and Queensland and the Northern Territory are phasing ionisation out.

NEVER MISS A DEAL!

Sign up to receive our emails with our latest promotions, offers and advice.


    Checkpoint Group Australia is an Australian supplier and specialist in fire safety, emergency warning, communications and workplace safety solutions for construction, mining and industrial applications.

    Email: sales@checkpointgroup.com.au

    Telephone: 1800 273 473

    Address: 30 Faunce Street, Queanbeyan, NSW 2620, Australia

    SPECIALISTS IN INNOVATIVE, COMPLETE FIRE & SAFETY SOLUTIONS

    Checkpoint Group Australia is an Australian supplier and specialist in fire safety, emergency warning, communications and workplace safety solutions for construction, mining and industrial applications.

    Email: sales@checkpointgroup.com.au

    Telephone: 1800 273 473

    Address: 30 Faunce Street, Queanbeyan, NSW 2620, Australia

    © Checkpoint Group AU | Master Security Licence 000104641.

    Website & Marketing by Maisona

    We Accept

    VisaPayPalMastercard MaestroAmerican Express